Leica HDS6000 (HDS)
The Leica HDS6000 features several major “next generation” advances that increase the versatility, portability,
and productivity of ultra high-speed, phase-based laser scanning for many as-built survey applications.
The HDS6000 replaces its popular predecessor, the Leica HDS4500 scanner, and takes ultra high-speed, phase-based laser scanning to the next generation with these features:
- 50% greater range, based on ambiguity interval
- New compact design with scanner, scan control panel, data storage, and battery integrated into a single, easy-to-carry unit
- New tilt sensing that allows traversing and resectioning
- Three scanner control options: integrated side panel, wireless PDA, or full laptop control
- Higher accuracy for each single point measurement
- Twice the maximum scan density
- Integrated battery and data storage- Unmatched portability
- Ultra-high speed scanning- Reduces time needed
- Built-in control panel- Easy, standalone use without laptop or PDA
- Integrated dual-axis (tilt) sensor- Better QA plus efficient traverse workflows that require fewer scan targets
Leica HDS6000 Product Specifications
| General |
| Instrument type | Compact, phase-based, dual-axis sensing, ultra high-speed laser scanner,
with survey-grade accuracy and full field-of-view |
| User interface | Onboard touch panel, or external notebook or Tablet PC, or PDA |
| Scanner drive | Servo motor |
| Data storage | Integrated hard drive |
| Camera | No integrated camera; Cyclone SCAN supports use of external camera |
| System Performance |
| Accuracy of single measurement |
| Position* | 6mm, 1m to 25m range; 10mm to 50m range |
| Distance* | ≤4mm at 90% albedo up to 25m;
≤5mm at 18% albedo up to 25m
≤5mm at 90% albedo up to 50m;
≤6mm at 18% albedo up to 50m |
| Angle (horizontal/vertical) | 125 µrad/125 µrad, one sigma |
Modeled surface precision**/noise | 2mm at 25m; 4mm at 50m, for 90% albedo, one sigma;
3mm at 25m; 7mm at 50m, for 18% albedo, one sigma |
| Target acquisition*** | 2mm std. deviation |
| Dual-axis sensor | Selectable on/off; 3.6" resolution |
| Data integrity monitoring | Self-check at start-up; optional checks using Cyclone-SCAN |
| Laser Scanning System |
| Type | Phase-shift |
| Laser Class | 3R (IEC 60825-1) |
| Range | 79m ambiguity interval; 79m @90%; 50m @18% albedo |
| Scan rate | Up to 500,000 points/sec, maximum instantaneous rate;
Average time: see "Selectability Table" below |
| Scan resolution |
| Spot size | 3mm at exit (based on Gaussian definition) + 0.22mrad divergence;
8mm @25m; 14mm @50m |
| Selectability | 5 pre-set spacings per table |
| Pts/360° (vert., horiz.) | Scan time (full dome) |
| "Preview" | 1250 | 25 sec |
| Middle (4x) | 5000 | 1 min 40 sec |
| High (8x) | 10000 | 3 min 22 sec |
| Super High (16x) | 20000 | 6 min 44 sec |
| Ultra High (32x) | 40000 | 26 min 40 sec |
|
| Point spacing at range | @10m | @50m |
| "Preview" | 50.6x50.6mm | 250x250mm |
| Middle (4x) | 12.6x12.6mm | 62x62mm |
| High (8x) | 6.3x6.3mm | 31.4x31.4mm |
| Super High (16x) | 3.1x3.1mm | 15.8x15.8mm |
| Ultra High (32x) | 1.6x1.6mm | 7.9x7.9mm |
|
| Field-of-view (per scan) |
| Horizontal | 360° (maximum) |
| Vertical | 310° (maximum) |
| Aiming/Sighting | Optical horizontal sighting using QuickScan™ feature |
| Scanning Optics | Vertically rotating mirror on horizontally rotating base;
Environmentally protected by shield |
| Scan motors | Direct drive, brushless; proprietary |
| Power transfer | Onboard rotating turret or external to non-rotating base |
| Data transfer | Ethernet or USB 2.0 device (two ports) |
Data storage capacity (onboard) | 60 GB, min |
| Communications | DHCP client/server; Ethernet or Bluetooth |
| Status indicators | 4-line alphanumeric display for laser status,
system power & status 1 LED for laser status |
| Level indicator | External bubble; digital readout on touch panel or via laptop |
| Electrical |
| Power supply | 24V DC; 90 - 260V AC |
| Power Consumption | 50 W |
| Battery Type | Integrated: Li-ion; External: sealed lead acid |
| Duration | Internal: 1.5 hrs, typical; External: 4 hrs, typical |
| Power status indicators | LEDs indicate charging status and capacity levels |
| Environmental |
| Operating temp. | 0° C to +40° C |
| Storage temp. | -20° C to +50° C |
| Lighting | Fully operational between bright sunlight and complete darkness |
| Humidity | Non-condensing |
| Physical |
| Scanner |
| Dimensions | 7.5" D x 11.5" W x 13.8" H; 190mm D x 244mm W x 351.5mm H |
| Weight | 14 kg, nominal (includes integrated battery) |
| Battery (external) |
| Dimensions | 9.5" D x 10" W x 12" H; 240mm D x 260 mm W x 300mm H |
| Weight | 16 kg, nominal |
| AC Power Supply |
| Dimensions | 9.5" D x 5" W x 6" H; 240mm D x 127 mm W x 152mm H |
| Weight | 2.5 kg, nominal |
| Data exchange |
| Import | Cyclone native IMP object database format,
Cyclone Object Exchange (COE) format,
ASCII point data (XYZ, SVY, PTS, PTX, TXT);
Leica X-function DBX, LandXML, ZFS, ZFC, 3DD |
| Export | ASCII point data (XYZ, SVY, PTS, PTX, TXT);
Leica X-function DBX, LandXML, PTZ |
All ± accuracy specifications are one sigma unless otherwise noted.
* At 1m - 50m range, one sigma
** One sigma; subject to modeling methodology for modeled surface
*** Algorithmic fit to planar HDS gray & white targets
|
For pricing options and packages, contact us at 800.220.7206